DN80 sewage electromagnetic flowmeter

Sewage electromagnetic flowmeter measurement principle:

It is the principle of magnetic line cutting. When the liquid flows, the magnetic force lines are cut, so that the flow velocity of the liquid is analyzed. Then, the real-time volume of the liquid is calculated through the flow rate x pipe and the section. The main components of lt-lde magnetic flowmeter sensor are: measuring tube, electrode, excitation coil, iron core and yoke shell.


Related questions about the flow meter can be consulted: Coating Manager QQ

Second, sewage electromagnetic flowmeter product features

l All-digital processing, strong anti-interference ability, reliable measurement, high precision, flow measurement range up to 150:1

l Ultra-low EMI switching power supply, suitable for a wide range of power supply voltage variations, and good EMI resistance.

l Adopt 16-bit embedded microprocessor, fast operation speed, high precision, programmable frequency low-frequency square wave excitation, improve the stability of the flow measurement, low power consumption.

l Using SMD devices and surface mount (SMT) technology, the circuit has high reliability.

l There are no moving parts in the pipeline, no blocking parts, and there is almost no pressure loss during the measurement.

· Sewage electromagnetic flowmeter with different materials of lining and electrodes have good corrosion resistance

·Not affected by media, density, viscosity, temperature, pressure and conductivity

Low-frequency rectangular wave excitation, less susceptible to interference, stable and reliable

Low energy consumption of the converter, simple and convenient installation, users do not need to debug

·Can bring lower limit alarm

Related questions about the flow meter can be consulted: Coating Manager QQ

Third, the main technical parameters of sewage electromagnetic flowmeter

. Nominal diameter series DN (mm)

Piping PTFE liners: 10, 15, 20, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600

Piping rubber linings: 40, 50, 65, 80, 100, 125, 150, 200, 300, 350, 400, 500, 600, 800, 1000, 1200.

Flow direction: Positive and negative net flows. Turndown ratio: 150:1. Repeatability error: ± 0 of the measured value. 1%

Accuracy: 0.5, 1.0 (pipeline)

Measured medium temperature: ordinary rubber lining: -20 ~ +60 °C

High-temperature rubber lining: -20 to +90 °C

Teflon lining: -30 to +100 °C

High-temperature PTFE liner: -30 to +180 °C.

Rated working pressure: pipeline type: DN6 ~ DN80 ≤ 1.6Mpa, DN100 ~ DN250 ≤ 1.0Mpa,

DN300 ~ DN1200 ≤ 0.6Mpa.

Flow measurement range: flow measurement range corresponds to the flow rate range is 0.1 ~ 15m/s

Conductivity range: Conductivity of the fluid to be measured ≥ 5us/cm (integral type), most of the medium with water as its component, its conductivity in the range of 200 ~ 800 μ s/cm, can use the electromagnetic flowmeter to measure Its traffic.

Current output: 0 to 10mA


Static Synchronous Compensator

FGI`s FGSVG series static synchronous compensator (STATCOM) can enhance power transmission capacity, reduce power loss, compensate reactive power, control harmonics, suppress flicker, stabilize grid voltage, balance three-phase system, change system damping characteristics and improve system stability. FGI`s STATCOM series products can be widely used in petrochemical, power systems, metallurgy, electrified railways, urban construction and other industries.